VP-302 High Temperature Penetrant, Type 2, Method C

Type: II

Method: C

Sensitivity Level: N/A

VP-302 is a special application high temperature (125-350˚F, 51.6-176.6˚C) inspection penetrant. It finds wide use in field weld and weld repair inspection. It is used in the inspection of refinery

processing equipment that is at elevated temperatures, speeding up the inspection process time by eliminating the cool down required for standard penetrant processing. Protective gloves should be worn while working on hot surfaces to avoid burns.
For Method C applications use only with R-502 remover.
For Developer applications use only D-702 developer.

Description

Product Data Sheet: Download

Bulk Safety Data Sheet: Download

Certified to SAE AMS 2644F and on the Qualified Parts List.

Approvals: VP-302 is listed on the approved products list for MIL-I-25135C.

It is low in sulfur, chlorine, fluorine and other halogens, making it safe for use on titanium and high nickel alloys found in nuclear components.