Method C: Visible Penetrant Solvent-Removable (Wipe-Off)
Guide to Method C processing per ASTM E-1417.
1. Pre Clean The Surface
Use Met-L-Chek® E-59A, R-503 or R-504 to remove oil, grease and other contaminants from the test surface. Part must be clean, dry, and at a temperature of 40-125°F (4.4-52°C) before penetrant is applied.
Products to Use:
2. Apply Penetrant
Apply Met-L-Chek® penetrant using spray, immersion, or wipe on. Wait a minimum of 10 minutes; 20 minutes if temperature is between 40-50°F (4.4-10°C) before proceeding to the next step.
Products to Use:
3. Removal
Moisten cloth with Met-L-Chek® remover and wipe penetrant from surface. Do not spray remover on surface to remove penetrant, as sensitivity will be impaired.
Products to Use:
E-59, E-59A, R-502, R-503, R-504:
4. Apply Developer
Apply non-aqueous Met-L-Chek® developer.
Products to Use:
5. Inspect
Wait a minimum of 10 minutes before inspection. Use illumination of > 100 foot candles (>1100 lux/m2) to inspect.